TRIPLETT
84-885
3-10
Model
Digital Multimeter
Instruction Manual
9007
Vue de la page 0
1 2 3 4 5 6 ... 47 48

Résumé du contenu

Page 1 - TRIPLETT

TRIPLETT84-8853-10ModelDigital MultimeterInstruction Manual9007

Page 2 - 1: INTRODUCTION

Page 92.34 Do not use this meter to measure current in circuits whose open circuit voltage exceeds 250V AC/DC. The meter’s fuses

Page 3

Page 102.37 Do not use the meter if it does not appear to work correctly on all ranges and in all modes. Failure to observe this precaution may re

Page 4

Page 112.41 To avoid damage to the meter and possible user injury, disconnect test leads from test points before changing the function/range. Fail

Page 5

Page 122.44 Avoid usage near strong RF elds (radio or television transmitters, walkie talkies, cellular phones, etc.). The meter may display rea

Page 6

Page 13 3: INTERNATIONAL SYMBOLSThe following International Symbols may be used in this manual and on the case of the meter to identify, caution, or w

Page 7

Page 14 4: PRODUCT FEATURES4.1 31 Measurement Ranges4.2 Huge 1.4” tall High Contrast LCD display4.3 White LCD Backlight allows viewing in

Page 8

Page 15 5: SPECIFICATIONS5.1 Display: ...1.4” (35mm) high LCD5.2 Display Resolution: ...2000 counts, 0000

Page 9

Page 16 20A / 250 volt FAST, 6 x 25mm, for 20A range. Triplett Part No. 3207-1345.13 Ins

Page 10

Page 17Note: a)Thefollowingaccuracyspecicationsarevalidat23degreesC,+/-5degreesC,RelativeHumiditylessthan75%b)Thespecicat

Page 11

Page 18AC Voltage200.0mV2.000V20.00V200.0V700V± (1.2% rdg + 5 digits)± (1.0% rdg + 3 digits)Input Impedance: Allrangesare10MΩFrequency:50Hzto

Page 12

1. Introduction2. Safety Rules and Warnings3. International Symbols4. Product Features5. SpecicationsTable of ContentsPage 16. Front Panel7. Measurem

Page 13

Page 19AC CurrentRange Resolution Accuracy2.000mA 1µA ± (1.2% rdg + 3 digits)200.0mA 100µA

Page 14 - 3: INTERNATIONAL SYMBOLS

Page 20Overload Protection: Allranges250VDCorACRMS.*On200MOhmrange,itisnormalforthemetertodisplay10LSDwiththetestleadss

Page 15 - 4: PRODUCT FEATURES

Page 21 6: FRONT PANEL1. LCD Display2. Power Button3. Function Switch4. 20A Input Jack5. uA and mA Input Jack6. COM Input Jack7. Volt, Ohm, Capaci

Page 16 - 5: SPECIFICATIONS

Page 227: MEASUREMENT PROCEDURESWARNING! Do not use the meter when the low battery symbol is displayed. This may cause the meter to produce

Page 17 - 5: SPECIFICATIONS CONT

7.3 DC Voltage Measurement:WARNING!If the magnitude of the voltage to be measured is unknown, always start by setting the meter to the highest range,

Page 18

Page 247.3.4 If the display indicates overrange, i.e. “1- - -”, disconnect the test probes from the circuit and rotate the RANGE switch

Page 19

Page 257.4 AC Voltage Measurement:WARNING!If the magnitude of the voltage to be measured is unknown, always start by setting the meter to the highes

Page 20

Page 267.4.4 If the display indicates overrange, i.e. “1- - -”, disconnect the test probes from the circuit and rotate the RANGE switch t

Page 21

Page 277.5 DC Current Measurement:WARNING!If the magnitude of the current to be measured is unknown, always start by setting the meter to the highes

Page 22 - 6: FRONT PANEL

Page 287.5.3 If the red test lead is inserted into the uA mA jack, set the RANGE switch to the 200m A position. Connect the

Page 23 - 7: MEASUREMENT PROCEDURES

Page 22: SAFETY RULES & WARNINGS2.1 Read all instructions in this manual before using this meter. Failure to do so may result i

Page 24

Page 297.6 AC Current Measurement:WARNING!If the magnitude of the current to be measured is unknown, always start by setting the meter to the highest

Page 25

Page 307.6.3 If the red test lead is inserted into the uA mA jack, set the RANGE switch to the 200m A~ position. Connect the test

Page 26

Page 317.7 Resistance Measurement:WARNING!Do not apply voltage or current to the meter when it is set to any of the “ Ω ” ranges.7.7.1 Connect the

Page 27

Page 327.7.5 If the displayed value is less than “200” (decimal point not shown), a more accurate reading may be obtained by setting

Page 28

Page 337.8 Continuity Beeper: WARNING!Do not apply voltage or current to the meter when it is set to the Diode Test / Continuity Beeper “

Page 29

Page 347.9 Diode Test: WARNING!Do not apply voltage or current to the meter when it is set to the Diode Test / Continuity Beeper “ ”

Page 30

Page 357.10 Measuring Capacitance: WARNING!Do not apply voltage or current to the meter when it is set to the Capacitance “F ” ranges. Do not connect

Page 31

Page 367.10.5 If the displayed value is less than “200” (decimal point not shown), a more accurate reading may be obtained by setting

Page 32

Page 37 8: TEST LEAD HOLDERS STAND, and HANGERTest Lead Holders are provided on the back of the 9007. The test leads may be snapped into the back of t

Page 33

Page 38 9: MAINTENANCEYour Triplett Model 9007 DMM is a precision measuring instrument and, when used as described in this manual, should not require

Page 34

Page 32.5 Follow the recommendations of any Trade Organizations or Regulatory Agencies whose scope encompasses the use of

Page 35

Page 399.1 Replacing Battery:9.1.1 Remove the test leads from the meter. 9.1.2 Remove 1 screw from the top of the battery compartment

Page 36

Page 409.2.3 Open the meter case by wiggling the back to separate it from the front. Set the back of the case to one side. 9.2.4 Locate

Page 37

Page 41 10: ACCESSORIES10.1 The Triplett Model 9007 package contains the following items: 10.1.1 The Model 9007 DMM 10.1.2 T

Page 38

Triplett Product Return InstructionsIn the unlikely event that you must return your Triplett equipment for repair, the following steps must be taken.

Page 39 - 9: MAINTENANCE

Triplett Three Year Limited WarrantyTriplett warrants instruments and test equipment manufactured by it to be free from defective material or workmans

Page 40

Triplett Three Year Limited WarrantyTo register a claim under the provisions of this warranty, contact Triplett’s Customer Service Department for a Re

Page 41

Triplett Three Year Limited WarrantyTriplett reserves the right to discontinue models at any time, or change specications, price or design, without n

Page 44

Page 4 precaution may result in damage to the meter or injury to the user.2.10 Make sure test leads are properly inse

Page 45

Page 52.14 Do not exceed the maximum voltage or current limitations of the meter (see product specications). Doing so may

Page 46

Page 62.20 Do not apply voltages to the input of the meter which are elevated above the earth ground potential by more than

Page 47

Page 72.25 Do not use meter in condensing atmospheres. That is, do not use meter in conditions where ambient temperature and

Page 48

Page 8 inserted into a household AC wall outlet.2.30 Do not touch the metallic portion of one test lead if the other tes