Model 90556-in-1 EnviroMeter with SoundLight, Temperature and HumidityInstruction ManualTRIPLETT84-89610/10
8 Failure to observe this precaution may result in damage to the meter or injury to the user. 2.13 Insert the test leads in the jacks
9 2.17 Do not attempt to measure a voltage source with the test leads plugged into the meter's uAmA or 10A jacks. Doing so may dama
10 hazard exists, when in fact, dangerous voltages or currents may be present. Failure to observe this precaution may result in damage to
11 2.26 Do not use the meter if either the meter or the test leads are wet, either from exposure to the weather, or after cleaning the case of
12 2.30 Do not touch the metallic portion of one test lead if the other test lead is connected to a live circuit. The current from the live circ
13 2.34 Do not use this meter to measure current in circuits whose open circuit voltage exceeds 600V AC/DC. The meter's fuses are rated at
14 2.37 Do not use the meter if it does not appear to work correctly on all ranges and in all modes. Failure to observe this precaution may result i
15 2.41 To avoid damage to the meter and possible user injury, disconnect test leads from test points before changing the function/range. Fa
16 2.44 Avoid usage near strong RF fields (radio or television transmitters, walkie talkies, cellular phones, etc.). The meter may displa
17 2.47 The Non-Contact AC Voltage Detector in the 9055 may not detect the presence of AC voltage in all situations. In particular, a t
18 3 FEATURES • Deluxe Autoranging DMM with Enviro Measurement • Built-in Light Level Meter (Lux) • Built-in Sound Level Meter (dBC) • Built-in A
19 • Auto or Manual Ranging • Auto Power Off • Rugged Overmolded Case Design • Built-in Stand and Test Lead Holders • Fused uA, mA, and A Rang
20 Storage temperature: 14 °F to 140 °F at less than 80 % relative humidity. Battery: Standard 9V, NEDA1604 or 6F22 battery. Dimensions: 6-5/8” x 3”
21 Photo detector: Silicon photo diode with filter mimicks spectral sensitivity characteristic of C.I.E. (International Commission on Ill
22 Internal Sensor in Meter (Room Temperature) Range Resolution Accuracy 32°F ~+122°F 0.1°F 3% of rdg ± 2 degrees 0°C ~+50°C 0.1°C 3% of rdg
23 Frequency Range: 50 to 400Hz Overload Protection: 600V CAT IV AC/DC 1000V CAT III DC 700V CAT III AC DC Current Range Resolu
24 AC Response: 50 Hz to 400 Hz Maximum Input: 400mA AC/DC on uA / mA ranges, 10A AC/DC on 10A range (30 seconds max every 15 minutes). R
25 Frequency Range Resolution Accuracy 5.000Hz 0.001Hz 50.00Hz 0.01Hz 500.0Hz 0.1 Hz 5.000kHz 1 Hz 50.00kHz 10Hz 500.0kHz 100Hz ± 1.2% of rdg
26 5. CONTROL LOCATIONS AND DESCRIPTIONS
27 CONTROL LOCATIONS AND DESCRIPTIONS (cont.) 1. Humidity & Temperature Sensor 2. LCD Display 3. Function Switch 4. V/Hz%/Ω/Cap/ Temp Input J
1 TABLE OF CONTENTS TITLE 1. INTRODUCTION………………………………………2 2. SAFETY INFORMATION …………………………4 3. FEATURES……………………………………………18 4.
28 14. Range Button Press to change from Autoranging to manual ranging. Press repeatedly to select the desired range. To return to Autoranging, pres
29 6. OPERATING INSTRUCTIONS Measuring Sound Level 1. Set the Function Switch to the “dBC” position. 2. Hold the face of the meter perp
30 Measuring Temperature (Room) 1. Place meter in the location to be measured. Allow meter to set in this location for at least 1 hour. 2. Set th
31 Measuring DC Voltage 1. Insert the black test lead into the COM jack and red test lead into the “V/Hz%/Ω/Cap/ Temp” jack. 2. Set the Func
32 Notes: Use the RANGE button to manually select the desired ACV range. The 400mV AC range can only be selected with the RANGE button. Use the REL b
33 Connect the red test probe tip to the positive side of the circuit. 8. Apply power to the circuit. 9. Read the current on the LCD display. Not
34 Measuring Frequency 1. Insert the black test into the COM jack and the red test lead into the V/Hz%/Ω/Cap/°C jack. 2. Set the Function S
35 4. Touch the test probes to the diode under test. Forward voltage will typically indicate 0.400 to 0.700V. Reverse voltage will indicate “OL”.
36 Note: The AC Voltage Sensor will not work in all situations. Metal in the vicinity can block the AC signal. Phase cancellation may make it appear
37 Battery and Fuse Replacement If “ “ appears on the LCD display, replace the battery. Remove 8 screws on the back cover and ope
2 1. INTRODUCTION The Triplett 9055 6-in-1 Digital Multi-Tester is an autoranging ruggedized 3-3/4 digit (4000 count) precision Digital Multimeter wi
38 Triplett Product Return Instructions In the unlikely event that you must return your Triplett equipment for repair, the following steps must be ta
39 Triplett Three Year Limited Warranty (cont.) If we are unable to repair or replace the product, we will make a refund of the purchase price. Consu
40 Triplett Three Year Limited Warranty (cont.) THE PROVISIONS OF THE WARRANTY ARE EXPRESSLY IN LIEU OF ANY OTHER WARRANTIES EXPRESSED OR IMPLIED. Th
3 The dBC Sound Level function is useful for measuring noise in factories, schools, hospitals, offices, airports, homes, etc….. and checking
4 2 SAFETY INSTRUCTIONS This meter has been designed with safety in mind, but like all products of this type, must be operated carefully to obtain th
5 2.1 Read all instructions in this manual before using this meter. Failure to do so may result in damage to the meter or injury to the use
6 2.5 Follow the recommendations of any Trade Organizations or Regulatory Agencies whose scope encompasses the use of this meter. Failu
7 2.9 Check the condition of the test leads before making a measurement. Do not use the test leads if there is damaged insulation or exposed met