7.7.5 If the displayed value is less than “200” (decimal point
not shown), a more accurate reading may be obtained
by setting the RANGE switch to a lower range. Rotate
the RANGE switch to the next lower position and
observe the reading on the LCD display. If the RANGE
switch is already on the lowest position (i.e. 200
Ohms), no greater measurement resolution can
be obtained.
Notes:
a)
T
he
2M, 20M,
and
200M
r
anges
r
equir
e
se
ver
al
seconds
to
sta
biliz
e
.
b)
The 200M range reads about 10 LSD high. To obtain an
accur
a
te
r
eading
, shor
t
the
test
leads
tog
ether
and
observ
e
the
r
esidual
r
eading
(usually 8
to
12 L
SD).
F
or
the
best
accur
ac
y
,
subtr
act
observed reading from subsequent
measurements.
c)
To obtain the most accurate reading on the 200
Ω
range, short
the
test
leads
tog
ether
and
note
the
r
esidual
r
esistance”
r
eading
.
It
is
typically
less
than
0.5
Ω
. Subtr
act
this
v
alue
fr
om
subsequent
readings on the
200Ω r
ang
e
.