DC VOLTAGE MEASUREMENTS
0-3 through 0-300 Volts:
1. Insert test leads in VOM and COM jacks.
2. Set Range Switch to appropriate DCV range.
3. Set Polarity Switch to desired polarity (310-C only)
4. Connect probes across circuit to be measured.
5. Energize circuit.
6. Read voltage on the black AC-DC scale.
0-1200 Volts: *
1. Insert test leads in COM and 1200 VDC* jacks.
2. Set Range Switch to 3 DCV position.
3. Set Polarity Switch to desired polarity (310-C only)
4. Connect probes across circuit to be measured.
5. Energize circuit.
6. Read voltage on the black AC-DC scale.
DO NOT TOUCH THE VOM while
it is connected to high voltage!
*Model 310-C is 0-600 Volts.