25
Triplett Model 9320-A
FIGURE 6
MEASURING AC AMPS
If it is desired to hold the reading, press the D-HOLD button so that the
annunciator is visible on the display.
WARNING!!!
WHENEVER TOUCHING THE METER IN AN ENERGIZED CIRCUIT, THE USE
OF A LINEMAN’S GLOVE CONFORMING TO ASTM D120, IS REQUIRED.
Remove the Meter from the circuit by opening the Jaws and carefully withdrawing
it.
Notes:
1) Although the Auto annunciator displays on the 400A range, there is only
one range on this setting, i.e. 400A.
2) Although the Hz/Duty button appears to function in the 400A~ and 1000A~
ranges, this feature is not available.